Spesifikasi Portable Turbidimeter 2100Q
Alat Ukur Kekeruhan
Portable Turbidimeter 2100Q
The portable 2100Q turbidity meter is ideal for use in the field or around the plant. It is easy to carry around and take multiple measurements from various collection points in your treatment process. With its intuitive user interface, the 2100Q makes it easy to take measurements and perform calibration and verification. Storing and transferring data from a portable turbidimeter has never been easier.
There is also an optional USB+Power module for the 2100Q portable turbidimeter, which allows you to transfer your data directly to a computer.
The 2100Q portable turbidimeter is compliant with USEPA Method 180.1 design criteria.
- Easy on-screen assisted calibration and verification
- Simple data transfer
- Accurate for rapidly settling samples
- Convenient data logging
- Optical system for precision in the field
Spesifikasi 2100Q Portable Turbidimeter
2100Q Portable Turbidimeter memiliki spesifikasi sebagai berikut:
Accuracy : ± 2 % of reading plus stray light
Battery Requirements : 4, AA
Certifications : CE certified
Compliance Certifications : CE/WEEE
Data logging : 500 records
Dimensions (H x W x D ) : 77 mm x 107 mm x 229 mm
Display Type : Graphic LCD
Enclosure Rating : IP67
Includes : Instrument, case assembly, 4 AA alkaline batteries, 6 sample cells, StablCal ampule kit, silicone oil, oiling cloth, manual.
Interface : Optional USB
Light Source : tungsten filament lamp
Max. operating humidity : 90 %
Measurement Method : Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) and transmitted light scatter signal
Measurement Modes : Normal (Push to Read), Signal Averaging, Rapidly Settling Turbidity
Operating Temperature Range : 0 to 50 °C
Path Length : 25 mm
Power Requirements : 100 - 240 V AC / 50/60 Hz (with optional Power or USB+Power module)
Power Requirements (Hz ) : 50/60 Hz
Power Requirements (Voltage) : 100 - 240 VAC
Power Supply : Batteries (see Battery Requirements) or Optional Power Supply
Range : 0 to 1000 NTU
Reading Modes : Normal (Push to Read)
Signal Averaging
Rapidly Setting Turbidity
Regulatory : EPA Method 180.1
Repeatability : ± 1 % of reading or 0.01 NTU , whichever is greater
Resolution : 0.01 NTU on lowest range
Response Time : 6 s in normal reading mode
Sample Cell Compatibility : 25 mm x 60 mm round
Sample Requirements : 15 mL (0.5 oz)
Sample Volume : 15 mL (0.5 oz)
Signal Averaging : Selectable on/off
Source Lamp : Tungsten filament lamp
Storage Conditions : -40 °C to 60 °C
Stray Light : < 0.02 NTU
Weight : 1.17 lbs. (0.53 kg) without batteries